25 YEARS OF MASTERING DRYING TECHNOLOGY
 
 
 
     
---------------------------------------------------------------------------------------------------------------------------------
   
 
Evaporation at the wet-end of a paper machine is often as high as the evaporation thru the drying process. Uncontrolled wet-end exhaust will cause the evaporation to dissipate over the building ceiling and eventually destroy the roof.

PremiAir provides the industry with wet-end and mist exhaust systems which are adapted to the different types of machines: exhaust volume is kept to a minimum by capturing mist and water droplets generated at the source.

Each of the above systems use high efficiency water droplet elimination units (cyclone, blades, etc.) within a sophisticated duct network design to prevent fiber and stock
build-up.

The Wet-End Exhaust System consists of exhausting the hot vapours to atmosphere from save-all connections, from underneath the wire, from strategically located cross machine headers, from ductwork located near the headbox, and from cleaning showers. The system will consist of exhaust ductwork, cross-machine duct, balancing dampers, an exhaust fan, a cyclonic droplets separator and an exhaust stack.
+
     
---------------------------------------------------------------------------------------------------------------------------------
 
 
The press Transfer Box consists of a specially designed cross machine header with high velocity air scraper to doctor by means of suction, the boundary layer of air between the first dryer running felt and the sheet. This phenomenon usually takes place between the first felt turning roll and the first top dryer of the paper machine. The Transfer Box is equipped with side seals of the sheet carrying felt developing therefore a suction air pad and stabilizing the sheet during the transfer.
+
---------------------------------------------------------------------------------------------------------------------------------


 
  © PremiAir Technology 2009 - Webmaster